Probe accuracy klipper
-
manually move your head to such coordinates and issue a GET_POSITION and enter the coordinates under probe_points. 000 Z:10. 987500, range 0. 21:17:10 rear left : x=56. Since this introduces quite a high deviation in the mesh points, i would like to Oct 26, 2022 · klipper v0. Jan 11, 2024 · lift_speed: 5. Probing the bed with 1mm/s speed helped a lot, but didn’t solve the problem completely. 117500, average 0. Not so for Bed Leveling and Probe. SET_SKEW XY=140. 002639. This directory has the specific klipper macros (and a link to RRF scripts), STL files properly oriented for printing and Feb 9, 2023 · You can try it by leveling the bed by hand and then pressing a probe on the bed while printing. Then one can just run START_PRINT and END_PRINT in the slicer's configuration. endstop_pin: PE1. Position the toolhead far from the bed, issue a G28 (or PROBE if not using probe:z_virtual_endstop), wait until the toolhead starts to move Jul 1, 2019 · You should use; PROBE_ACCURACY SPEED=1 X=10 Y=10 Z=60. This would be useful in the same way: To help tune and establish reliable homing speeds To help diagnose or troubleshoot failing switches vs other issues. Without the probe, move the nozzle to the center of the bed and perform a manual Z offset calibration by moving the nozzle down, step by step, until it barely touches the print surface. For instance with my voron the z-endstop accuracy is a Nov 28, 2022 · Probe takes a while to trigger/nozzle crashes into bed before probe can trigger but the probe does still trigger the probe tip needs adequate space to be able to probe. probe accuracy results: maximum 0. The accuracy test completed all probes without a single issue, which rules out a dodgy connection to the probe. Due to the organic and idiomatic nature of klipper, there is no standard method to deploy and retract a probe. Then, run the CALCULATE_SWITCH_OFFSET. Dec 18, 2022 · If you just want the z position, rather than the z_offset, you could try using the MANUAL_PROBE command, and then use {printer. This occurs after every x/y/z movement except the consecutive multi-probing z moves. 001mm? 14:20:33 probe accuracy results . Published Jan 9, 2023. Aug 16, 2020 · Recv: // probe accuracy results: maximum 10. Note that the canbus_query. After probing, a mesh is generated and z-movement is adjusted according to the mesh. Therefore, we offer a basic set of macros which serve as a framework for users to customize. Accuracy can be improved by calibrating, i. I’ve found out that my printer have some sort of problem with the readings while doing, for example, the probe_accuracy macro. 037380 My BLTouch config is (I have tested with the touch mode to false and trigger true as well): See the PROBE command for details on the optional probe parameters. It runs a little slower but not at the set value. Probe dock (all the printers use the same) Probe dock mount (what attaches to the printer to dock the probe when not in use) The CAD with all the files is located Here. This command tests the probe for repeatability (precision) and produces a standard deviation based on two or more probes of the same XY position. 02), but there are two results with 0. Multi-probing without stowing¶ By default, Klipper will deploy the probe at the start of each probe attempt and then stow the probe afterwards. You switched accounts on another tab or window. 190mm-. probe_accuracy_test_suite. Published Apr 5, 2023. I want to edit some of the created mesh-point-values after the probing is done, maybe via an extra macro. What i have tried is: inductive probe (5€), has shown an accuracy of appx. If in reality it is 30. It used to be perfect. manual_probe. Read on to learn how to set up and use the BLTouch with Klipper! Advertisement. 1 running Klipper and OctoPrint. 2mm, so a standard deviation of 0. Feb 2, 2023 · Describe your issue: I had to replace my Omron switch to another Omron switch but I think the accuracy of this switch is poor. See the MANUAL_PROBE command for details on the SPEED parameter and the additional commands available while the tool is active. I love klipper and increase the quality and the affidability of the printer. 1mm increase. Then I switched to the original and was about 0,005. 038906, standard deviation 0. The probe z_offset will then be calculated from these measurements. The absolute z position in mm to move to before moving to the next position. 7. 017500, average 1. However, when the drivers are in this mode, no special Klipper configuration is needed and the advanced Klipper features discussed in this document are not available. Please note, the PROBE_CALIBRATE command uses the speed variable to move in XY direction as well as Z. 244000, range 0. The speed is correct for “PROBE_ACCURACY”. Length AD = 99. 002358; 9mm/s: median 1. 3mm If there is not enough clearance the probe will not activate in Nov 7, 2023 · To date, over 500,00 probe deploy-probe-retract cycles with a moving Z-axis dock have been performed. You should be around -0. 8. Calibrating probe Z offset. Custom CoreXY cold with a TriangleLab probe: 2:49 PM probe accuracy results: maximum 0. 4 Fysetc Spider 1. But running it again introduces the increase. It is often convenient to define custom macros in the Klipper config file instead - such as: [gcode_macro START_PRINT] and [gcode_macro END_PRINT]. The gathered data was compiled and analyzed to compare the performance between different switch manufactures and models. 5 micron. If the printer is commanded to a position X0 Y0 Z10 during a print, then the goal is for the printer's nozzle to be exactly 10mm from the printer's bed. 1 Then I did a PROBE_ACCURACY test with 50 samples in the same corner of the bed that the mesh calibration starts (and fails) in. # See docs/Command_Templates. 172625, median 3. Jun 18, 2023 · Accuracy is defined as: The ability of a measurement to match the actual value of the quantity being measured. 010000, average 3. Here are my results: 1mm/s: median 2. If beacon is within ranging distance, a ranging measurement is used. 0, y=203. 4 R2 with Klicky Proble. The following macros are fundamental and will hopefully get one printing upon commissioning. cabinfourus June 26, 2022, 11:25pm 5. So this isn't really unexpected behavior. New posts Search forums. Bed mesh boundaries: This will help you configure your bed mesh min and max points to match the values calibrated in the See the PROBE command for details on the optional probe parameters. Z_OFFSET_APPLY_PROBE¶ Wondering if it is possible to pull the median value result from a PROBE_ACCURACY into a macro. Unfortunately, he doesn’t. 1mm higher tan the prior sample. 020625, range 0. Each device will have a unique identifier. Please attach the klippy. Move the nozzle to the center of the bed and perform a manual Z offset calibration by moving the nozzle down, step by step, until it barely touches the print surface. There it takes the set value. Jun 24, 2023 · It seems that when I run a PROBE_ACCURACY test each sample is roughly 0. 3. I illustrate the problem and how i can reproduce it. I power on the printer, run a G28 for homing and run probe_accuracy macro. 0-613-gebc3b0de moonraker v0. Test the probe accuracy with PROBE_ACCURACY: probe accuracy results: maximum 1. 01-0. 506948. The downside is that this elongates the probing process. 03/27. 1-747-g779997c mainsail v2. The klipper macros are here, the RRF here. I dont want my switch pressed to hard or crash again :) Press manualy the switch. 007500, average 1. 503000, median 0. Aeche March 1, 2023, 2:25pm 3. KlickyProbe STL's are now located on each probe type directory. log to your next post. First layers can be hard to get right. : if tolerance > samples_tolerance, discard the one with the biggest deviation from the mean and sample a single new point (instead of N new samples). 020000, average 2. If one requires a less common G-Code command The z_offset is the distance between the nozzle and bed when the probe triggers. Klipper’s goal is to support the G-Code commands produced by common 3rd party software (eg, OctoPrint, Printrun, Slic3r, Cura, etc. On the one hand I like the accuracy of the CR-Touch and on the other hand the ‘no moving parts’ of the inductive probe, since the probe_accuracy命令允许使用不同的参数进行测试,以了解它们的影响 - 请参阅g-code文档了解更多细节。 如果探针在大多数情况下能获得可重复的结果,但偶尔会出现异常值,那么可以增加在每个探测点的探测次数来解决这个问题--详见 配置参考 中关于探针 samples PROBE¶ PROBE [PROBE_SPEED=<mm/s>] [LIFT_SPEED=<mm/s>] [PROBE_METHOD=<contact|proximity>]: Perform a Z probe operation. 092500, minimum 8. 264000, minimum 2. Dec 1, 2022 · Klipper & BLTouch: How to Make Them Work Together. Repeat probe_accuracy until you're satisfied. To address this, the branch adds the command Z_TILT_CALIBRATE. PROBE_ACCURACY¶ Feb 4, 2024 · So finally Mark changed to code seemingly back to the original one and now the probe_accuracy behaves like expected with the following result for my BD-sensor: 14:49. Klipper gcode_macro. The z_offset is the distance between the nozzle and bed when the probe triggers. e. During this guide, it may be necessary to make changes to the Klipper config file. 695000, minimum 1. This section provides a list of steps to help confirm the pin settings in the Klipper printer. 991250, median 1 Klipper supports calibrating the delta parameters via a manual probing method or via an automatic Z probe. However, if I run them again after some time, the readings are consistent within the set, but they report a different Z value to the previous PROBE_ACCURACY. Further, should the printer then be commanded to a position of X50 I received my Euclid Probe a week or so ago to replace a failing inductive probe. 5, 90 # update for your machine. 0 (for example: 0. Thanks! The status reference documentation doesn't mention it. 5) Restart the Klipper firmware. A number of delta printer kits come with automatic Z probes that are not sufficiently accurate (specifically, small differences in arm length can cause effector tilt which can skew an automatic probe). 10. 035 and 0. Is that good I think it is but is klicky better. Switching to unclicky didn’t fix the problem as well. Doing QGL, Probe_Calibrate or Probe_Accuracy, all OK. Finally, run probe_accuracy with a sample size of 1000. 689525, median 1. 14:49. 76000 : adjust CW 00:01. Printer specific STL are in each printer directory. Z_OFFSET_APPLY_PROBE¶ Navigate to the OctoPrint terminal tab and run the PROBE_ACCURACY command. endstop_pin: probe:z_virtual_endstop. 4, Legacy and Trident printers. Or may be you need to invert the behaviour of the sensor, in this case: endstop_pin: !PE1. The PROBE_CALIBRATE command will operate from whatever X,Y coordinates you run it at. cfg. Bed Mesh also cannot compensate for mechanical and electrical issues. You may now use the SET_SKEW gcode to configure skew_correcton. Navigate to the OctoPrint terminal tab and run the PROBE_CALIBRATE command to start the tool. As you can see, most of the time the range is quite ok (0. The right line must look like this one. Jan 16, 2023 · Basic Information: Current Klipper Version | Mainsail Hi everyone, I have a question regarding the bed_mesh. Probes come in many flavors and as such have varying levels of accuracy, reliability, and repeatability, depending on several factors. Please do not always delete the template when you open a new thread. 3. 727435, range 0. so i thought lets run probe_calibrate within the command pallet of the fluidd ui. z_hop: 3. Read on to learn all about how it's done! In Klipper, Z offset calibration is a basic but important procedure. This document serves as a guide to performing bed leveling in Klipper. This document describes Klipper's stepper phase adjusted endstop system. Default Tests Included 1 test, 30 samples at each bed mesh corners - check if there are issues with individual z drives. cfg (6. 003375. 179000, minimum 3. 006229. Apr 25, 2023 · Set the switch_offset to any value greater 0. Update your printer. Initial Startup Checks. Z_OFFSET_APPLY_PROBE¶ BED_MESH_CALIBRATE [METHOD=manual] [<probe_parameter>=<value>] [<mesh_parameter>=<value>]: This command probes the bed using generated points specified by the parameters in the config. Aug 9, 2019 · You signed in with another tab or window. CR-Touch (50€), has shown an accuracy of appx. If everything is correct, it will print an estimated switch offset. There are a few changes you'll need to make in order to get Tap working properly. Looks like you're out of luck. z_position} to find the current Z position. 945453, standard deviation 0. If you run it while positioned at 0,0 then it will try to run from there. Jul 29, 2022 · Mesh is generated with the probe, so the coordinates are given WRT the probe to make sure the probe actually can reach the intended positions and are actually on the bed and not beside the bed. The distance between the minimum and the maximum value is called the range. If the layer thickness changes when the switch triggers, there is your problem. 995000, minimum 1. This can # be used to attach the probe after probing on the nozzle and before probing # on the mag-probe. Z_OFFSET_APPLY_PROBE¶ probe_accuracy命令允许使用不同的参数进行测试,以了解它们的影响 - 请参阅g-code文档了解更多细节。 如果探针在大多数情况下能获得可重复的结果,但偶尔会出现异常值,那么可以增加在每个探测点的探测次数来解决这个问题--详见 配置参考 中关于探针 samples Adjusting bed leveling screws using the bed probe¶ This is another way to calibrate the bed level using the bed probe. e. Author. Compare it to your print layer height, usually something like 0. If you want to use the probe for homing you need to change the endstop_pin to probe:z_virtual_endstop. but when running probe_calibrate it always result in a negative z-offset You signed in with another tab or window. 684395 klippy. With Klipper, BLTouch probes automate the mesh bed levelling process. 003,0. 0 for min and max, not around 6mm. 690000, standard deviation 0. If the printer doenst stop (speed=1 ist very slow) turn of the printer. It are always the same, “correction values”, but different ones for the specific probe-points and all of them are relative to the measured values. That’s why I came up with the idea of changing “max_z_velocity” with a command. log The text was updated successfully, but these errors were encountered: Jan 26, 2023 · 05:18:07 // Klipper state: Ready 05:18:29 $ G28 05:19:12 // probe at Forums. Jan 18, 2023 · I discovered a weird Problem with inconsistencies of the first up to three probes when doing a PROBE_ACCURACY or Mesh. Axis limits: This calibrates the travel range of each axis and configures the printable area in the slicer. It's important to understand the goal of bed leveling. 728685, standard deviation 0. The deviation was about 0,4mm at some tests. This can be used to # detach the probe afterwards. Klipper's goal is to support the G-Code commands produced by common 3rd party software (eg, OctoPrint, Printrun, Slic3r, Cura, etc. homing_retract_dist: 0 # beacon needs this to be set to 0. As for getting the value in the original macro, you might be able to use a gcode_macro for a global variable, and storing the value there. 560000, minimum 0. cfg, I've Mar 12, 2023 · Setting the Z Offset in Klipper doesn't have to be hard. Nov 7, 2023 · klipper Macro examples. In the above example, 11aa22bb33cc is the micro-controller's "canbus_uuid". g. So I switched back to my original Omron switch. 249000, median 2. 140453, standard deviation 0. In Klipper, Z offset calibration is a basic but important procedure. You signed out in another tab or window. For example, if your measured lengths along XY are as follows: Length AC = 140. 169000, range 0. This is what the klipper documentation states: A "step distance" is rotation_distance/ (full_steps_per_rotation*microsteps). Published Dec 1, 2022. 002784 The highly accurate, magnetically coupled Z-Probe that is not affected by bed temp, bed material, magnetism or surface treatment. Here you will find the necessary files and documentation to print and setup your own klicky probe. ) in their standard configurations. The minimum safe z height is 3mm. 0, z=0. end_gcode: # A list of G-Code commands to run after each calibration command. Instead, Klipper prefers human readable "extended G-Code commands". This functionality can improve the accuracy of traditional endstop switches. Klipper supports calibrating the delta parameters via a manual probing method or via an automatic Z probe. Redo step 2 until samples_tolerance_retries is exceeded or the tolerance criterion is met. Navigate to the OctoPrint terminal tab and run the PROBE_CALIBRATE command to start Klipper’s probe calibration tool. Reload to refresh your session. EddyMI3D October 26, 2023, 7:30pm 2. Yes. EddyMI3D January 12, 2024, 11:03am 4. 677500, range 0. It is not a goal to support every possible G-Code command. Once you've got the firmware up and running, learn how to work the probe accuracy results: maximum 1. Apr 5, 2023 · Klipper: Z Offset Calibration – Simply Explained. 000. Jul 30, 2022 · Suppose you have connected your sensor to a pin called PE1, as an example. cfg as recommended in Tap Klipper Instructions; Home Z and test virtual Z endstop by lifting tool-head; Heat soak your machine and run a couple probe_accuracy samples=100 to "break-in" your probe; Run a few more probe_accuracy checks (default of 10 probes) Make sure [skew_correction] is in printer. Advertisement. probe accuracy results: maximum 3. 001871; 5mm/s: median 2. Once you've got the firmware up and running, learn how to work the Klipper bed mesh compensation. 107500, range 1. Calibrate probe z-offset. 002497, average 0. Instead of letting the probe pin touch the print bed, let it touch the nail on your finger. It is installed on a Voron 2. If i press Bed_Mesh_Calibrate, the toolhead pic… Mar 28, 2021 · If the bed is not 100% level, probing only 3 points can lead to a (reproducibly) non-level bed. Recv: // and read 10 times with speed of 5 mm/s. probe accuracy1660×1532 237 KB. 037125, median 0. I have a BLTouch probe and my leveling procedure has gone like this: Ensure the gantry is parallel to the table. 729932, minimum 0. After a couple of probes (usually from the second on), it stabilises at ± 1 ADC Step around a certain value. Run a CALIBRATE_Z. cfg, inside [stepper_z], you should not write. See how the numbers keep increasing after each probe? something is odd here. 042813, minimum 0. 246500, standard deviation 0. This is pretty standard for what I’ve been seeing with the 8mm inductive probes. SET_SKEW can be used to configure skew correction for the XY plane. 7 KB) klippy. by Matteo Parenti. 022187, average 0. If so, can someone kindly show me the syntax. 05mm from the get go. 003375mm is a small fraction of that, so very good. Navigate to the OctoPrint terminal tab and run the PROBE _ACCURACY command. As comparision: In Marlin I Useful to prevent the z endstop pin sticking to the nozzle and being pulled out of the assembly. 006021. Just did it on one of my printers. Length BD = 142. log (2. Example: endstop_pin: probe:z_virtual_endstop. Each screenshot is a different Omron switch - D2F. Slicers will often allow one to configure "Start G-Code" and "End G-Code" sequences. Navigate to the OctoPrint terminal tab and run the PROBE_ACCURACY command. Redo probe calibrate while cold according to Klipper instructions. Feb 7, 2024 · I’m in search of a probe with high accuracy to use with ABL. After completing the BL-Touch control pin and sensor pin tests, it is now time to test probing, but with a twist. Generally the distance in height from the tip of the probe to the tip of the nozzle should be within 2. 2 printer. I have got my printer working with klipper, but have been having an issue with leveling sensor that I can't figure out. Providing an accurate probe Z offset is critical to obtaining high quality prints. Your Z configuration may need to be updated for beacon homing: [stepper_z] endstop_pin: probe:z_virtual_endstop # use beacon as virtual endstop. 8,99. 3-4. by Andreas Giencke. Otherwise a dive is made to the trigger point, and then a ranging measurement is used. 001500 This is pretty standard for what I’ve been seeing with the 8mm inductive probes. SCREWS_TILT_CALCULATE probes all 3 screw locations without this 0. The Klipper PROBE_CALIBRATE tool can be used to obtain this value - it will run an automatic probe to measure the probe's Z trigger position and then start a manual probe to obtain the nozzle Z height. When I run probe accuracy, the z height is always increasing until I home the printer again, then it starts all over again. 337953, standard deviation 0. Euclid Probe™️ uses screw attached magnets to a PCB for both mechanical coupling and for electrical contacts and dimensional accuracy. Save that to your config. Endstop phase. Feb 28, 2023 · If yes, simply choose some coordinates that are. 08:16:22 // probe accuracy results: maximum 0. I'm new to klipper. 0 °C outside and a temperature sensor reads 30. Homing Z axis resets this increase. Update your Z endstop: Under the [stepper_z] block, you'll want to comment out your position_endstop and change your endstop_pin so that it uses the virtual Z endstop for Tap. To enable this feature, one would determine the nozzle coordinates such that the Z probe is above the screws, and then add them to the config file. correcting / offsetting against a known good source. I have been able to home and run many probe accuracy It should be noted that software based correction will not achieve perfect results, it can only approximate the shape of the bed. 7 MB) Describe your issue: after a months of running the printer fine i started to notice that the offset was a bit off. Docking and undocking klicky proble also ok. Tuning motor current¶ A higher driver current increases positional accuracy and torque. Set the safe x-y position for z homing (typically the bed center): [safe_z_home] home_xy_position: 107. For some type of setups X & Y accuracy can be more or less important. 985000, average 8. 953500, median 8. Here is a quick guide to tuning your X, Y, and Z Offset. I was actually watching this video today that went over this topic. See the PROBE command for details on the optional probe parameters. In addition to this document, be sure to review the TMC driver config reference. md for the G-Code format. 171500, standard deviation 0. To use it you must have a Z probe (BL Touch, Inductive sensor, etc). 000 Y:0. Feb 19, 2024 · IMG_71571920×1440 240 KB. Don’t forget to download all the necessary parts. Instead stick to it and provide the requested information. safe_z_height: 2 # default is 2 * z_offset from the "probe:z_offset" section. If an axis is skewed or a probe is not accurate then the bed_mesh module will not receive accurate results from the probing process. 0 °C, then this sensor is accurate. A typical endstop switch has an accuracy of around 100 microns. Then I switched to Klipper and made the accuracy test (PROBE_ACCURACY) and was shocked. 0375. Custom CoreXY cold with a TriangleLab probe: 2:49 PM. 4,142. Start by homing the printer and then move the head to a position near the center of the bed. Run the CALCULATE_SWITCH_OFFSET. Dec 11, 2019 · Klipper overall seems to be really slow to even notice the trigger, easiest way to see it is to run PROBE_ACCURACY with varying speeds. This is based on the instructions found at: Sep 22, 2021 · Therefore, I suggest to adapt a similar workflow for multiple probing, i. Feb 11, 2024 · General Discussion. The mesh is generated from “the point of view” of the nozzle and not of the probe (this makes it very important that the offsets are highly accurate) May 16, 2023 · Basic Information: Printer Model: ender 3 v2, bltouch MCU / Printerboard: 4. To address this, klipper allows to probe in more than 3 points and does a least-squares approximation to find the optimal positions. roughly in the middle of your bed for X and Y. 8,V2. Feb 8, 2024 · Just did it on one of my printers. 9 to 0. shortly above your bed in Z. Jan 9, 2023 · Klipper: Bed Mesh – Simply Explained. Klicky Probe for Vorondesign V1. This command will run the probe ten times and produce output similar to the following: Recv: // probe accuracy: at X:0. So my advice, try the magnet thing or switch to the original. Doing Homing of all axis no errors occur. The only probe docking failures were due to operator error: not updating the probe Z-offset between sample changes. py tool will only report uninitialized devices See the PROBE command for details on the optional probe parameters. Capable of operating up to 80C natively, higher temps available. 2. It is most useful when using a Trinamic stepper motor driver that has run-time configuration. Then, in the printer. Read on to learn all about how it's done! If configuring this value on a "clone" or older BL-Touch device, be sure to test the probe accuracy before and after setting this value (use the PROBE_ACCURACY command to test). Updating your Klipper config for Tap. Probe offsets: This will help you calibrate not only the z-offset but also the X and Y offsets for your probe. Then print a big first layer test and babystep the Z until your offset is correct. Jul 13, 2022 · V2. 209mm with the high and low spots always in the same place, so I know that the probe accuracy is repeatable for 3 samples averaged. py is a collection of tests to help checking probe accuracy, precision and drift under different conditions. Z_OFFSET_APPLY_PROBE¶ Oct 26, 2023 · The speed option under the [bed_mesh] section controls the speed in which the probe moves between points not probe Z speed. It drifts as it probes. 4. Instead, Klipper prefers human readable “extended G-Code commands”. Saved searches Use saved searches to filter your results more quickly Apr 26, 2021 · Verify probe repeatability under Marlin as well as under Klipper → both should show the same accuracy; Compare Klipper’s mesh with Marlin’s mesh under the same settings (mesh size, starting point, probe count etc. Feb 9, 2024 · This is a request to include an equivalent function to PROBE_Z_ACCURACY or PROBE_ACCURACY for X & Y endstops. 501250, standard deviation 0. Sep 23, 2022 · For instance, getting rounded values is a perfectly normal thing for Klipper, but getting the uncertainty down to 0. Be sure to issue a RESTART command after every change to the config file to ensure that the change takes effect (type “restart” in If uninitialized CAN devices are detected the above command will report lines like the following: Found canbus_uuid=11aa22bb33cc, Application: Klipper. Jun 23, 2022 · jakep_82 June 26, 2022, 5:23am 4. 728185, median 0. You’re currently telling the printer to use the diag pin on the Z driver for sensorless homing which is not a safe way to home and could lead to a head crash. 442500, range 0. 001500. Ensure the extended probe tip is mounted below the nozzle. The problem is that I can't run a bed mesh, as during the 150 (7*7*3) probings there will The z_offset is the distance between the nozzle and bed when the probe triggers. probe accuracy results: maximum 2. I just want to be able to do this when homing the z-axis because the single sample might be off by 0. When I run PROBE_ACCURACY, I get very consistent readings within that run. ) → Both should graphically give the same “bed shape” (use the same tools for visualizing, not Marlin Octoprint and The bed mesh delta is very consistently in the range 0. Recv: // probe at -0. 750000, standard deviation 0. I've printed out the parts and installed the probe using the same wiring and Fysetc port (pin PA3) that I was using for the inductive probe Unfortunatly, after loading euclid. cfg file. 005 is z=2. 10 micron. Apr 28, 2023 · See docs/Command_Templates. za ci or se jl bk ds bw kh rl